APC GALAXY VS uninterruptible power supply (UPS) Double-conversion (Online) 50 kVA 50000 W

SKU
GVSUPS50KR0B5HS
Login for pricing
Out Of Stock - Contact for availability
Double-conversion, 50000VA, Sinewave, 460V 40/70Hz, 415V 50/60Hz, VRLA 480V, Mini tower, White
Galaxy VS UPS 50kW 400V with N+1 power module, for 5 smart modular 9Ah battery strings, Start-up 5x8
Highly efficient, easy-to-deploy 50kW, 400V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. This UPS is for up to 5 smart modular high capacity battery strings, but is supplied without batteries, so you can easily customize the battery runtime. Includes 5x8 start-up service and one additional power module for N+1 redundancy.
Includes: Dust filter, EcoStruxure Ready, Installation Manual, Integrated network management, Start-up service.

Compatible with Schneider Electric's lithium ion battery solution
Reduces system footprint and weight, cooling and maintenance requirements, and total cost of ownership; offers double the life of VRLA batteries; and improves backup storage predictability and manageability.

Embedded Network Management Card
Allows you to remotely manage alert thresholds and monitor your UPS over EcoStruxure IT, Web, SNMP, or Modbus TCP and Modbus RTU.

Built-in backfeed protection
Full built-in backfeed contactor ensures that no electricity is sent back to the grid.

Parallel-redundant capable
Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy

Flexible DC bus
Optimizes battery sizing and supports a wide range of energy storage technologies, including VRLA, Li-ion, and NiCd batteries.

Parallel-capacity capable
Increases total power capacity by using multiple uninterruptible power supplies simultaneously.

EcoStruxure IT Expert
From your smartphone or computer, connect to our cloud-based, do-it-yourself monitoring system that collects, organizes, and distributes critical alerts and key information in real time, providing a unified view of even highly distributed physical infrastructure environments. Optimize your uptime and maintenance planning, and anticipate infrastructure issues before they occur with advanced analytics and performance benchmarking. Available in select countries.

Front-access servicing
Simplifies installation and UPS maintenance while minimizing space requirements.

Modular UPS design
Provides design redundancy and fast serviceability with improved mean time to repair, via self-diagnosing, field-replaceable modules.

Multiple levels of service offers
With the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like Schneider Electric to do for you.

ECOnversion mode
Operating mode that ensures ultra high efficiency while charging the batteries, conditioning the load power factor and ensuring a Class 1 output voltage regulation.

High efficiency in double conversion mode
Consistently high power quality at high efficiency, even at low load levels. Any disturbances on the distribution waveform are regenerated via the zero transfer time AC to DC then DC to AC conversion process. The battery is only used as a back-up source.

Input Power Factor Correction
Minimizes installation costs by enabling the use of smaller generators and cabling.

Robust operation
No power derating in kW up to 40 degrees C or 104 degrees F.

Wide input voltage range
Designed for harsh electrical environments to save battery life.
SKU GVSUPS50KR0B5HS
EAN 0731304410140
Specification
Power
Output voltage regulation-0.1%
Input power factor0.99
Output power50000 W
Input operation voltage (min)340 V
Input operation voltage (max)460 V
Output operation voltage (min)380 V
Output operation voltage (max)415 V
Output voltage Total Harmonic Distortion (THD)3%
Input current Total Harmonic Distortion (THD)3%
Crest factor2.5:1
Output power capacity50 kVA
Charging current136 A
ECO modeYes
Performance
UPS topologyDouble-conversion (Online)
WaveformSine
Noise level54 dB
Audible alarm(s)Yes
Features
Output frequency50/60 Hz
UPS topologyDouble-conversion (Online)
WaveformSine
Output voltage regulation-0.1%
Input power factor0.99
Output power50000 W
Input operation voltage (min)340 V
Input operation voltage (max)460 V
Output operation voltage (min)380 V
Output operation voltage (max)415 V
Output voltage Total Harmonic Distortion (THD)3%
Noise level54 dB
Input current Total Harmonic Distortion (THD)3%
Crest factor2.5:1
Audible alarm(s)Yes
Output power capacity50 kVA
ECO modeYes
Input frequency40/70 Hz
Charging current136 A
Battery
Battery voltage480 V
Battery technologySealed Lead Acid (VRLA)
Charging current136 A
Design
International Protection (IP) codeIP20
Form factorMini Tower
Product colourWhite
Display typeLCD
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 40 °C
Operating relative humidity (H-H)0 - 95%
Storage relative humidity (H-H)10 - 80%
Operating altitude0 - 990 m
Technical details
Output frequency50/60 Hz
Harmonized System (HS) code85078000
Compliance certificatesRoHS
Weight & dimensions
Package width755 mm
Package depth1010 mm
Package height2082 mm
Weight250 kg
Width550 mm
Package weight250 kg
Height1970 mm
Depth847 mm
Packaging data
Package width755 mm
Package depth1010 mm
Package height2082 mm
Package weight250 kg
Logistics data
Harmonized System (HS) code85078000
Manufacturer APC
In Stock No